Counting Controller For People Counting
|
Counting Controller For People Counting
To be used with any counting sensor, turnstile, etc. and OTOT Counting and Monitoring SW.
Description:
- OTOT's people counting controller, collects, analyze and display the total number of people entered, exited and currently inside in the site.
- It can not only monitor, but also control the access, by automatic closing the gates, according to pre-set counting numbers.
- Another poplar use is to turn on a sign such as: "FULL", when certain amount of people are currently inside the venue.
- The controller accept inputs from any counting device: turnstiles, sensors, etc.
- It shows the number of people entered into the site, exit from the site, and how many people are in the site at the moment. .
Application environments:
- Sport Stadiums and Arenas, gym, swimming pools
- Clubs, Casinos, Theme Parks, Museums, Galleries...
- Retail: Shopping Centers, Stores & Shops, Retail Parks
- Hotels and other hospitality venues
- Airports, Ports and Stations (passenger/pedestrian movement control)
- Smart Buildings (environmental & resource management)
- General Security & Surveillance
Highlights:
- The basic counting source came from any sensor which provide one "entry pulse" for each person entering the site, and one "exit pulse" for each person exit the site.
- Example for sensors types:
- Overhead Thermal Detector
- Infrared IR counting sensor
- Turnstiles
- Manually pushbutton switch
- Road Loop Detector- for cars
Basic configuration:
- The controller has 4 inputs. Each input may be set (by the customer) to be either: Enter, Exit or
A/B : bi directional, two sensors set.
- The pulses may be 24VDC pulse, or "dry contact" pulse.
- Minimal pulse duration time: 0.02 sec.
- Maximum distance from the source of pulses to the controller, using standard copper cable: 1,000 meters.
- The controller count the pulses and display the counting information on the 16 Characters, 2 lines LCD display.
- Optional: TCP/IP port, to be connected to local or remote PC.
- Controlling: The controller has 3 outputs which can be used for many functions such as:
- Turn on/off lights, at certain counting number
- Activate "over capacity" buzzer or lighted sign
- Close or open gates or turnstiles, when the site is full
- Optionally, more outputs can be provided, locally or remotely.
- The setting and using of the outputs is easy: Each output is programmed, by the customer, to be activated at X amount of people, either from the "enter", "exit", or "present".
- For example: if your site is limited to 1000 people, you can set output No. 1 (N.C. contacts) to be activate at 1000 "in site" ("present") , and connect the turnstile to this output.
- When the count came to 1000, the turnstile would close automatically.
- If one person go out- the number become 999- so one person can go in….
- The controller's keyboard is used for: (password required)
-
- Reset counting memory to zero.
- Changing Password
- Changing date and time (optional)
- Changing automatic reset time (optional)
- Setting the inputs type: entry, exit or a/b couple.
- Setting the output relays configuration and parameters.
|